Outcomes of robotic sacrocolpopexy

Article information

Obstet Gynecol Sci. 2023;66(6):509-517
Publication date (electronic) : 2023 July 18
doi : https://doi.org/10.5468/ogs.23073
1Department of Obstetrics and Gynecology, Korea University Guro Hospital, Seoul, Korea
2Department of Obstetrics and Gynecology, Korea University College of Medicine, Seoul, Korea
Corresponding author: Jung-Ho Shin, MD, PhD, Department of Obstetrics and Gynecology, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul 08308, Korea, E-mail: lateroman@gmail.com
Received 2023 March 9; Revised 2023 May 28; Accepted 2023 June 15.

Abstract

This review aimed to summarize the complications and surgical outcomes of robot-assisted sacrocolpopexy. Nineteen original articles on 1,440 robotic sacrocolpopexies were reviewed, and three systematic reviews and meta-analyses were summarized in terms of intraoperative, perioperative, postoperative, and/or surgical outcomes. Robotic sacrocolpopexy has demonstrated low overall complication rates and favorable surgical outcomes. Nevertheless, long-term follow-up outcomes regarding objective and/or subjective prolapse recurrence, reoperation rates, and mesh-related complications remain unclear. Further research is required to demonstrate whether the robotic approach for sacrocolpopexy is feasible or can become the modality of choice in the future when performing sacrocolpopexy.

Introduction

In 2014, Wu et al. [1] reported that the cumulative lifetime risk for pelvic organ prolapse (POP) surgery was 13%, and the age-specific annual risk for POP surgery increased progressively by the age of 80 years. They also reported that the number of women experiencing POP is expected to double by 2050 [1]. Despite advances in surgical techniques, the rate of reoperation after primary prolapse repair remains high and is estimated to be 10–30% [2,3]. Due to the high recurrence rate of conventional native tissue repair procedures [4], the use of sacrocolpopexy (SCP), which uses artificial meshes to suspend the vagina, is increasing worldwide [3,5]. Although SCP has proven to be the gold standard procedure for apical support due to its durability, its risks, such as high morbidity rates after a long operation time, chances of massive presacral bleeding when approached by laparotomy [6], and poor ergonomics and long learning curves of surgeons when performing laparoscopy [7], have made them reluctant to attempt SCP. However, the introduction of a robotic platform in SCP has changed the atmosphere [8,9]. The advantages of three-dimensional magnified vision, dexterity with multi-wristed instruments, surgeon comfort and ergonomics, and a shorter learning curve compared to the laparoscopic approach make it suitable for dissecting deep into the narrow field, mesh placement, and multiple intracorporeal suturing [7,8,10]. However, drawbacks, such as cost, lack of tactile sensation, and lack of high-quality evidence, should not be overlooked [7,8]. Although a few recent studies have emerged, long-term outcomes have not yet been thoroughly evaluated.

In this review, we aimed to describe the surgical techniques of robotic SCP under the da Vinci SP system® (Intuitive Surgical Inc., Sunnyvale, CA, USA) and to discuss the current evidence of surgical outcomes of robotic SCP.

Surgical techniques

Two types of da Vinci® surgical platforms (Intuitive Surgical Inc., Sunnyvale, CA, USA), da Vinci Xi® and da Vinci SP®, can be used for SCP; we mainly used the da Vinci SP® platform. The da Vinci SP® system, built for single-incision robotic surgery, allows the insertion of three instrument arms and a flexible endoscope camera through a single 2.5 cm cannula. This allows a narrow and deep access for surgeons to reach the pelvis. In addition, both the camera and the instruments have additional joints that allow for more degrees of freedom. In “cobra mode”, the camera is flexed 30° in the midline to allow an ideal view of the instruments, and camera angles can be adjusted further according to the surgeon’s needs. Although the flexible endoscope constrains the field of surgical view to be narrower, improved control of the optics compensates for these limitations. Additional joints in the instruments are also helpful for mesh fixation because precise control and versatility of movements at different angles and directions are required when suturing in a limited space.

For single-site robotic SCP under the da Vinci Si® and Xi® system, straight robotic arms were docked on four trocars through a single 2.5 cm umbilical incision. Three 8-mm cannulas were inserted into the umbilical glove port: one for the endoscope and the other for the docking of additional robotic arms. However, crowding and clashing among semi-rigid instruments inserted through separate curved cannulas, insufficient power, and limited degrees of freedom for precise instrument control during procedures present as challenges for this modality [1113].

The surgical steps were as follows: first, all patients were prepared for lithotomy in a steep Trendelenburg position with a left table tilt of approximately 15°. The robotic patient cart was not located between the patient’s legs, allowing the assistant to place a uterine and/or vaginal manipulator during the procedure. The SP® trocar was placed in a multichannel single-incision port through a 2.5–3.0 cm vertical umbilical incision. A monopolar spatula or large needle driver was used for the right robotic arm (3 o’clock), Cadiere forceps for the left arm (9 o’clock), and fenestrated bipolar forceps for the centrally positioned arm (6 o’clock) (Fig. 1). Then, an accessory 5-mm trocar, serving as laparoscopic assistance, was inserted approximately 10–12 cm to the right of the umbilicus according to the complexity of the procedure, such as the presence of pelvic adhesions and/or obesity.

Fig. 1

Insertion of instruments of the da Vinci SP® system. Monopolar spatula at the right-sided arm (3 o’clock), cadiere forceps for the left arm (9 o’clock), and the fenestrated bipolar forceps for the centrally positioned arm (6 o’clock).

Briefly, an arrow-shaped dissection was performed to reveal the vesicovaginal space, possibly to the level near the perineal membrane (Fig. 2), and a V-shaped dissection along the rectovaginal space was performed as far as the perineal body was performed [14,15] (Fig. 3). While dissecting the rectovaginal space, the endoscope was manually rotated to set up an upward view. The retroperitoneal tunneling method was applied from the sacral promontory to the dissected pouch of Douglas [16] (Fig. 4). A partially absorbable type I polypropylene Y-shaped mesh was attached to the vaginal wall using absorbable sutures, and the tail end of the mesh was attached to the anterior longitudinal ligament of the S1 using nonabsorbable sutures. Finally, the peritoneum was approximated over the mesh [17].

Fig. 2

Anterior dissection and mesh attachment.

Fig. 3

Posterior dissection and mesh attachment.

Fig. 4

Retroperitoneal tunneling method.

Complications of robotic SCP

Intraoperative complications

1) Visceral injury

Cystotomy, during vesicovaginal dissection, is the most common intraoperative complication of SCP. In two systemic reviews and meta-analyses, the pooled estimates of the cystotomy rates during robotic SCP were 2.6% and 2.0%, respectively [10,18]. Interestingly, study cohorts consisting of post-hysterectomy vault prolapse showed higher cystotomy rates, reaching up to 12.5% [1921], while the cohort mostly with supracervical hysterectomy (SCH) reported a lower cystotomy rate of 0–6% [13,2225]. In a prospective study, Culligan et al. [22] reported no cystotomy in 316 robotic SCP cases, and the study population included approximately 75% of patients with concomitant SCH. Similarly, Mourik et al. [26] reported no cystotomy during 50 sacrohysteropexy procedures. However, two retrospective studies with a cohort of patients with post-hysterectomy vault prolapse only reported cystotomy rates of 11.1% and 12.5%, respectively [19,20]. Confounders may exist for the results since intraoperative visceral injuries largely depend on the surgeon’s experience, and the patient’s and operative characteristics. Nevertheless, caution is required when dissecting the vesicovaginal space of a post-hysterectomy vaginal vault. Once cystotomy occurs, one- or two-layered closure using absorbable sutures is performed, followed by a leakage test by instilling dye into the bladder. A catheter is then placed for 5–14 days, depending on the size and location of the injury. A cystogram is required before catheter removal, and reepithelialization of the bladder and restoration of its strength can be expected within 3–4 days and after 21 days, respectively. When a trigonal injury is suspected during the urogenital diaphragm approach, “call expert” and concerns regarding the ureter and/or urethra should be taken [27].

For intraoperative bowel injury, several studies have been conducted. Matthews et al. [28] reported two proctotomies out of 85 operations, and Germain et al. [29] reported one enterotomy out of 52 cases, whereas Anand et al. [20] reported four cases of bowel injury among 50 robotic SCP to correct post-hysterectomy vaginal vault prolapse. Two recent randomized studies by Illiano et al. [30] and Matanes et al. [13] showed no bowel injuries in 113 robotic SCP. Two systematic review articles reported rates <1% [10,18].

The vaginotomy rate was consistent with that of other visceral injuries. Most articles demonstrated zero or one vaginotomy, whereas one study involving post-hysterectomy vault prolapse reported a rate as high as 24% (11/45) [20].

2) Presacral bleeding

Dissection of the sacral region for mesh fixation is considered the most critical step during the SCP procedure. Disruption of the middle sacral vessels, sacral venous plexus, and/or left common iliac vein can cause drastic hemorrhage. Thus, identification of these vessels and caution regarding their anatomical variations during the procedure are important. According to a comprehensive review of abdominal SCP by Nygaard et al. [6], the incidence of hemorrhage or transfusion during SCP is 4.4%, with some cases arising from presacral hemorrhage. Few studies on robotic SCP have included presacral bleeding as an intraoperative complication. van Zanten et al. [23] reported one presacral bleeding out of 130 robotic SCP cases in their prospective study, whereas Anand et al. [20] found two presacral hemorrhages out of 50 robotic SCP operations in their retrospective cohort. Both studies reported that the surgical route was changed due to presacral bleeding. Anger et al. [31] presented one left iliac venotomy in 40 robotic SCP cases that closed intraoperatively without changing the access route. The risk of presacral hemorrhage during robotic SCP is quite low and is estimated to be lower than that associated with the conventional abdominal approach. Optimal magnification with a three-dimensional view and multi-articulated instruments that allow fine dissection to distinguish adjacent structures may have contributed to the decreased risk of accidental injury to the surrounding vessels.

Perioperative outcomes

We defined perioperative outcomes using estimated blood loss (EBL), operation time (from incision to closure), and length of hospital stay, which reflect the safety or short-term morbidity of the surgery. Most studies demonstrated that the average EBL during robotic SCP is minimal (range 50–250 mL), and the length of hospital stay ranges from 1 to 7 days, with an average of 2 days [10,18]. Although a few studies have reported console time, we listed the total operation time (from skin incision to closure) to evaluate the perioperative outcome of robotic SCP, which appears consistently in the literature. A systematic review by Hudson et al. [18] showed that the weighted average total operative time was approximately 230 minutes, and another systematic review presented a median of 194 minutes [10]. Recently, robotic SCP using a single-incision (both single-site and single-port) technique reported a total operation time of less than 200 minutes [13,17,24,25]. This does not mean that single-incision SCP takes less time, since operative time is influenced by many factors, such as the surgeon’s proficiency; thus, the total operation time cannot be the sole indicator for the index surgery. However, easier docking system of SP® platform may have contributed to shorter total operation time.

Mesh-related complications

Mesh-related complications are a specific issue in SCP, and smoking, chronic steroid use, mesh type, and concurrent hysterectomy are known risk factors for mesh-related complications [2,32,33].

Siddiqui et al. [34] observed a total mesh erosion rate of 4.3% (3/70) and no mesh erosion among concomitant SCH groups during an 18-month mean follow-up period. The study by Mourik et al. [26] which consisted of 50 uterus-preserving sacrohysteropexy cases, reported no mesh complications, and a study by Chan et al. [19] whose inclusion criterion was post-hysterectomy vault prolapse, showed similar results (0/16). In contrast, Geller et al. [35] demonstrated a 13.3% (2/15) mesh erosion rate in their prospective non-comparative study, with 75% of patients undergoing total hysterectomy. However, in a retrospective study comparing robotic SCP with total hysterectomy and SCH, the two groups demonstrated insignificant differences in the mesh erosion rate at the 1-year follow-up (7.5% vs. 2.3%; P=0.35) [36].

Currently, most studies have reported mesh-related outcomes with the application of a type I (macroporous) lightweight monofilament polypropylene mesh, which has a lower mesh complication rate [6,33]. All the aforementioned studies used this type of mesh.

Several reviews have reported SCP mesh erosion rates, and the results were comparable between different access modalities. Traditionally, in a comprehensive review of abdominal SCP, the risk of mesh erosion was 3.4%, and polypropylene meshes were reported to have a lower incidence at 0.5% [6]. A recent review of mesh exposure after minimally invasive SCP, including either laparoscopic or robotic SCP, indicated that the overall rate of mesh exposure was 3.5% [33]. In two systematic reviews of robotic SCP, the pooled estimates of mesh erosion rates were 2.0% and 4.1%, respectively [10,18].

An extended Colpopexy and urinary reduction efforts trial, which represented a long-term 7-year follow-up outcome of abdominal SCP, showed that the occurrence of mesh erosion tends to increase over time, reaching 10.5% [37]. This risk can change as more evidence of robotic SCP accumulates. Nevertheless, the incidence of mesh exposure after robotic SCP is low (2–4%) based on the currently available data. Furthermore, studies reporting mesh erosion rates demonstrate much fewer cases of reoperation for mesh complications; the most common site for mesh exposure is the vagina, and most cases can be managed conservatively with topical estrogen without surgical intervention.

Surgical outcomes

A meta-analysis by Hudson et al. [18] for the surgical outcomes of robotic SCP yielded a combined estimated apical success rate of 98.6% (95% confidence interval [CI], 97.0–100.0%) with the definition of apical prolapse as less than or equal to pelvic organ prolapse quantification stage I. Notably, they reported that the reoperation rate for recurrent prolapse was 3.3%, and the reoperation rates for recurrent apical and non-apical prolapse were 0.8% and 2.5%, respectively. The majority of reoperations were posterior colporrhaphies. Another meta-analysis demonstrated that the overall objective cure rate, irrespective of the vaginal compartment, ranges from 84% to 100% [10]. Although the criteria used to determine surgical success or failure vary wherein even apical and non-apical prolapses are defined differently within the studies, the overall success rate for robotic SCP is promising (Table 1).

Various surgical failure or success criteria for robotic sacrocolpopexy and the respective outcomes

In general, risk factors for surgical failure after pelvic reconstructive surgery include younger age, obesity, family history, and advanced prolapse stage [2,3840]. In terms of SCP, the approaches (abdominal vs. laparoscopic vs. robotic), types of mesh, and mesh anchoring methods (absorbable vs. nonabsorbable sutures, interrupted vs. barbed running sutures, and anchor vs. suture) were suggested as possible factors for surgical failure. However, corresponding randomized studies have proven that none of these factors were significant [21,31,4146]. Further research is required to determine the existence of robotic SCP-specific predictors of prolapse recurrence. To date, differences in surgical outcomes between multiport, single-site, and single-port robotic approaches showed insignificant results [13,17,24,25].

Given that a paramount of prolapse repair is the restoration of quality of life, studies presenting their outcomes by applying composite measures of success are on the rise (Table 1). The subjective success rate measured through structured queries also showed promising outcomes, significantly improving prolapse and urinary, defecatory, and sexual functions with a high satisfaction rate.

Similar to the mesh-related problems, prolapse recurrence can increase over time. Thus, long-term data collection of patients undergoing robotic SCP is required.

Recently, two studies comparing the outcomes of single-site and single-port robotic SCP, which included 127 and 74 cases, respectively, were published [17,25]. Although evidence is limited, the two modalities seem to be comparable in terms of intraoperative, perioperative, postoperative, and surgical outcomes. Additional joints of the instruments including the endoscope are the advantage of SP® system, which can reach deep into the urogenital diaphragm from the sacral promontory, while single-site system faces setbacks by crowding and clashing among the semi-rigid instruments resulting to a limited range of motion.

Conclusion

The purpose of this review was not to determine the superiority or inferiority of robotic SCP over other modalities of SCP. This review is written in a noncomparative and narrative manner with several outstanding studies on robotic SCP so that readers can collectively overview the data regarding robotic SCP in various aspects at this time point. This review also comes from the limited reports on single-incision robotic SCP. To the best of our knowledge, most of the related articles deal mainly with surgical techniques and tips regarding their initial experience of single-incision robotic SCP [12,16,47,48]. For this reason, comparing outcomes of robotic SCP among multiport, single-site, and single-port approaches seem undesirable; however, it may still possess future research value.

Nonetheless, the overall low intraoperative, perioperative, and postoperative complication rates reflect that robotic SCP can be performed safely, and has a promising surgical success rate. In addition, most of the comparative studies quoted above have proven the non-inferior surgical outcomes of robotic SCP compared to laparotomy or laparoscopic access. Therefore, surgeons dealing with the pelvic organ prolapse should consider the advantages of the robotic approach for SCP, which can be performed safely and effectively. Currently, research is emerging on single-incision robotic SCP, particularly when performed using a single-port robotic platform [17,24,25,48]. The specific complications and surgical outcomes of single-port robotic SCP should be discussed in the near future.

Notes

Conflict of interest

No potential conflict of interest relevant to this article was reported.

Ethical approval

Institutional Review Board (IRB) approval is not applicable for this study.

Patient consent

There is no need for patient consent in this review article.

Funding information

None.

References

1. Wu JM, Matthews CA, Conover MM, Pate V, Funk MJ. Lifetime risk of stress incontinence or pelvic organ prolapse surgery. Obstet Gynecol 2014;123:1201.
2. Pelvic organ prolapse: ACOG practice bulletin, number 214. Obstet Gynecol 2019. 134e126–42.
3. Dällenbach P. To mesh or not to mesh: a review of pelvic organ reconstructive surgery. Int J Womens Health 2015;7:331–43.
4. Maher C, Baessler K, Glazener CM, Adams EJ, Hagen S. Surgical management of pelvic organ prolapse in women. Cochrane Database Syst Rev 2007. (4)CD004014.
5. Haya N, Baessler K, Christmann-Schmid C, de Tayrac R, Dietz V, Guldberg R, et al. Prolapse and continence surgery in countries of the Organization for Economic Cooperation and Development in 2012. Am J Obstet Gynecol 2015;212:755e1–27.
6. Nygaard IE, McCreery R, Brubaker L, Connolly A, Cundiff G, Weber AM, et al. Abdominal sacrocolpopexy: a comprehensive review. Obstet Gynecol 2004;104:805–23.
7. Callewaert G, Bosteels J, Housmans S, Verguts J, Van Cleynenbreugel B, Van der Aa F, et al. Laparoscopic versus robotic-assisted sacrocolpopexy for pelvic organ prolapse: a systematic review. Gynecol Surg 2016;13:115–23.
8. Moreno Sierra J, Ortiz Oshiro E, Fernandez Pérez C, Galante Romo I, Corral Rosillo J, Prieto Nogal S, et al. Long-term outcomes after robotic sacrocolpopexy in pelvic organ prolapse: prospective analysis. Urol Int 2011;86:414–8.
9. Gala RB, Margulies R, Steinberg A, Murphy M, Lukban J, Jeppson P, et al. Systematic review of robotic surgery in gynecology: robotic techniques compared with laparoscopy and laparotomy. J Minim Invasive Gynecol 2014;21:353–61.
10. Serati M, Bogani G, Sorice P, Braga A, Torella M, Salvatore S, et al. Robot-assisted sacrocolpopexy for pelvic organ prolapse: a systematic review and meta-analysis of comparative studies. Eur Urol 2014;66:303–18.
11. Shin HJ, Yoo HK, Lee JH, Lee SR, Jeong K, Moon HS. Robotic single-port surgery using the da Vinci SP® surgical system for benign gynecologic disease: a preliminary report. Taiwan J Obstet Gynecol 2020;59:243–7.
12. Matanes E, Lauterbach R, Mustafa-Mikhail S, Amit A, Wiener Z, Lowenstein L. Single port robotic assisted sacrocolpopexy: our experience with the first 25 cases. Female Pelvic Med Reconstr Surg 2017;23:e14–8.
13. Matanes E, Boulus S, Lauterbach R, Amit A, Weiner Z, Lowenstein L. Robotic laparoendoscopic single-site compared with robotic multi-port sacrocolpopexy for apical compartment prolapse. Am J Obstet Gynecol 2020;222:358e1–11.
14. Ercoli A, Campagna G, Delmas V, Ferrari S, Morciano A, Scambia G, et al. Anatomical insights into sacrocolpopexy for multicompartment pelvic organ prolapse. Neurourol Urodyn 2016;35:813–8.
15. Muavha DA, Ras L, Jeffery S. Laparoscopic surgical anatomy for pelvic floor surgery. Best Pract Res Clin Obstet Gynaecol 2019;54:89–102.
16. Liu J, Bardawil E, Zurawin RK, Wu J, Fu H, Orejuela F, et al. Robotic single-site sacrocolpopexy with retroperitoneal tunneling. JSLS 2018;22:e201800009.
17. Oh S, Bae N, Cho HW, Park YJ, Kim YJ, Shin JH. Learning curves and perioperative outcomes of single-incision robotic sacrocolpopexy on two different da Vinci® surgical systems. J Robot Surg 2023;17:1457–62.
18. Hudson CO, Northington GM, Lyles RH, Karp DR. Outcomes of robotic sacrocolpopexy: a systematic review and meta-analysis. Female Pelvic Med Reconstr Surg 2014;20:252–60.
19. Chan SS, Pang SM, Cheung TH, Cheung RY, Chung TK. Laparoscopic sacrocolpopexy for the treatment of vaginal vault prolapse: with or without robotic assistance. Hong Kong Med J 2011;17:54–60.
20. Anand M, Woelk JL, Weaver AL, Trabuco EC, Klingele CJ, Gebhart JB. Perioperative complications of robotic sacrocolpopexy for post-hysterectomy vaginal vault prolapse. Int Urogynecol J 2014;25:1193–200.
21. Paraiso MFR, Jelovsek JE, Frick A, Chen CCG, Barber MD. Laparoscopic compared with robotic sacrocolpopexy for vaginal prolapse: a randomized controlled trial. Obstet Gynecol 2011;118:1005–13.
22. Culligan PJ, Lewis C, Priestley J, Mushonga N. Long-term outcomes of robotic-assisted laparoscopic sacrocolpopexy using lightweight Y-mesh. Female Pelvic Med Reconstr Surg 2020;26:202–6.
23. van Zanten F, van Iersel JJ, Paulides TJC, Verheijen PM, Broeders IAMJ, Consten ECJ, et al. Long-term mesh erosion rate following abdominal robotic reconstructive pelvic floor surgery: a prospective study and overview of the literature. Int Urogynecol J 2020;31:1423–33.
24. Nam G, Lee SR, Roh AM, Kim JH, Choi S, Kim SH, et al. Single-incision vs. multiport robotic sacrocolpopexy: 126 consecutive cases at a single institution. J Clin Med 2021;10:4457.
25. Lee SR, Roh AM, Jeong K, Kim SH, Chae HD, Moon HS. First report comparing the two types of single-incision robotic sacrocolpopexy: single site using the da Vinci Xi or Si system and single port using the da Vinci SP system. Taiwan J Obstet Gynecol 2021;60:60–5.
26. Mourik SL, Martens JE, Aktas M. Uterine preservation in pelvic organ prolapse using robot assisted laparoscopic sacrohysteropexy: quality of life and technique. Eur J Obstet Gynecol Reprod Biol 2012;165:122–7.
27. Fagan Matthew. Preoperative and postoperative complications and management. In : Alfred EB, Geoffrey WC, Steven ES, eds. Ostergard’s urogynecology and pelvic floor dysfunction 6th edth ed. Philadelphia (PA): Lippincott Williams & Wilkins; 2008. p. 328–9.
28. Matthews CA, Carroll A, Hill A, Ramakrishnan V, Gill EJ. Prospective evaluation of surgical outcomes of robot-assisted sacrocolpopexy and sacrocervicopexy for the management of apical pelvic support defects. South Med J 2012;105:274–8.
29. Germain A, Thibault F, Galifet M, Scherrer ML, Ayav A, Hubert J, et al. Long-term outcomes after totally robotic sacrocolpopexy for treatment of pelvic organ prolapse. Surg Endosc 2013;27:525–9.
30. Illiano E, Ditonno P, Giannitsas K, De Rienzo G, Bini V, Costantini E. Robot-assisted Vs laparoscopic sacrocolpopexy for high-stage pelvic organ prolapse: a prospective, randomized, single-center study. Urology 2019;134:116–23.
31. Anger JT, Mueller ER, Tarnay C, Smith B, Stroupe K, Rosenman A, et al. Robotic compared with laparoscopic sacrocolpopexy: a randomized controlled trial. Obstet Gynecol 2014;123:5–12.
32. Cundiff GW, Varner E, Visco AG, Zyczynski HM, Nager CW, Norton PA, et al. Risk factors for mesh/suture erosion following sacral colpopexy. Am J Obstet Gynecol 2008;199:688.e1–5.
33. Deblaere S, Hauspy J, Hansen K. Mesh exposure following minimally invasive sacrocolpopexy: a narrative review. Int Urogynecol J 2022;33:2713–25.
34. Siddiqui NY, Geller EJ, Visco AG. Symptomatic and anatomic 1-year outcomes after robotic and abdominal sacrocolpopexy. Am J Obstet Gynecol 2012;206:435.e1–5.
35. Geller EJ, Parnell BA, Dunivan GC. Pelvic floor function before and after robotic sacrocolpopexy: one-year outcomes. J Minim Invasive Gynecol 2011;18:322–7.
36. Myers EM, Siff L, Osmundsen B, Geller E, Matthews CA. Differences in recurrent prolapse at 1 year after total vs supracervical hysterectomy and robotic sacrocolpopexy. Int Urogynecol J 2015;26:585–9.
37. Nygaard I, Brubaker L, Zyczynski HM, Cundiff G, Richter H, Gantz M, et al. Long-term outcomes following abdominal sacrocolpopexy for pelvic organ prolapse. JAMA 2013;309:2016–24.
38. Schulten SF, Detollenaere RJ, IntHout J, Kluivers KB, Van Eijndhoven HW. Risk factors for pelvic organ prolapse recurrence after sacrospinous hysteropexy or vaginal hysterectomy with uterosacral ligament suspension. Am J Obstet Gynecol 2022;227:252e1–9.
39. Friedman T, Eslick GD, Dietz HP. Risk factors for prolapse recurrence: systematic review and meta-analysis. Int Urogynecol J 2018;29:13–21.
40. Oh S, Jeon MJ. How and on whom to perform uterine-preserving surgery for uterine prolapse. Obstet Gynecol Sci 2022;65:317–24.
41. Freeman RM, Pantazis K, Thomson A, Frappell J, Bombieri L, Moran P, et al. A randomised controlled trial of abdominal versus laparoscopic sacrocolpopexy for the treatment of post-hysterectomy vaginal vault prolapse: LAS study. Int Urogynecol J 2013;24:377–84.
42. Costantini E, Mearini L, Lazzeri M, Bini V, Nunzi E, di Biase M, et al. Laparoscopic versus abdominal sacrocolpopexy: a randomized, controlled trial. J Urol 2016;196:159–65.
43. Coolen AWM, van Oudheusden AMJ, Mol BWJ, van Eijndhoven HWF, Roovers JWR, Bongers MY. Laparoscopic sacrocolpopexy compared with open abdominal sacrocolpopexy for vault prolapse repair: a randomised controlled trial. Int Urogynecol J 2017;28:1469–79.
44. Matthews CA, Geller EJ, Henley BR, Kenton K, Myers EM, Dieter AA, et al. Permanent compared with absorbable suture for vaginal mesh fixation during total hysterectomy and sacrocolpopexy: a randomized controlled trial. Obstet Gynecol 2020;136:355–64.
45. Tan-Kim J, Nager CW, Grimes CL, Luber KM, Lukacz ES, Brown HW, et al. A randomized trial of vaginal mesh attachment techniques for minimally invasive sacrocolpopexy. Int Urogynecol J 2015;26:649–56.
46. Berger AA, Tan-Kim J, Menefee SA. Anchor vs suture for the attachment of vaginal mesh in a robotic-assisted sacrocolpopexy: a randomized clinical trial. Am J Obstet Gynecol 2020;223:258.e1–8.
47. Lee SR. Robotic single-site® sacrocolpopexy: first report and technique using the single-site® wristed needle driver. Yonsei Med J 2016;57:1029–33.
48. Ganesan V, Goueli R, Rodriguez D, Hess D, Carmel M. Single-port robotic-assisted laparoscopic sacrocolpopexy with magnetic retraction: first experience using the SP da Vinci platform. J Robot Surg 2020;14:753–8.
49. Gupta P, Ehlert M, Bartley J, Gilleran J, Killinger KA, Boura JA, et al. Perioperative outcomes, complications, and efficacy of robotic-assisted prolapse repair: a single institution study of 196 patients. Female Pelvic Med Reconstr Surg 2018;24:408–11.
50. Thomas TN, Davidson ERW, Lampert EJ, Paraiso MFR, Ferrando CA. Long-term pelvic organ prolapse recurrence and mesh exposure following sacrocolpopexy. Int Urogynecol J 2020;31:1763–70.

Article information Continued

Fig. 1

Insertion of instruments of the da Vinci SP® system. Monopolar spatula at the right-sided arm (3 o’clock), cadiere forceps for the left arm (9 o’clock), and the fenestrated bipolar forceps for the centrally positioned arm (6 o’clock).

Fig. 2

Anterior dissection and mesh attachment.

Fig. 3

Posterior dissection and mesh attachment.

Fig. 4

Retroperitoneal tunneling method.

Table 1

Various surgical failure or success criteria for robotic sacrocolpopexy and the respective outcomes

Study Inclusion Surgical outcome measures Result
Follow-up (month)a) Surgical success rates Reoperation for POP recurrence
Siddiqui et al. [34] POPQ stage II–IV
18.3 (6.7)
Anatomic failure:
  • -The vaginal apex descends more than one-third into the vaginal canal (i.e., POPQ point C >−2/3 TVL) OR

  • -The anterior or posterior vaginal wall descends beyond the hymen (i.e., POPQ points Aa, Ba, Ap, or Bp are >0)

Symptomatic failure:
  • -Bothersome vaginal bulge symptoms on question #3 of the PFDI-20b) OR

  • -Repeat surgery for prolapse occurs at any point during the follow-up period

Anatomic successc): 66/70 (94.3%)
Symptomatic successc): 79/86 (91.9%)
3/86 (3.5%)
Myers et al. [36] POPQ stage II–IV
12.8 (0.4)d)
Anatomic failure: equal or greater than stage II of any compartment
Composite success: no mesh exposure, no prolapse at or beyond point 0 on POPQ, and an answer of “no” to the prolapse-specific questions in the POPDI-6
Anatomic successe): 57/83 (68.7%)f)
Composite successe): 59/83 (71.1%)
NA
Gupta et al. [49] Baden-Walker grade 1–4g)
9 (0–85)
Anatomic success:
  • -Apical: less than Baden-Walker grade 2h)

  • -Non-apical: less than Baden-Walker grade 3i)

Apical successc): 182/186 (97.8%)
Overall successc): 169/186 (90.9%)
9/186 (4.8%)
Illiano et al. [30] POPQ stage III–IV
24.06 (20.8–36.1)
Anatomic success: prolapse stage <II for all compartments, point C≤−5 and at least 7 cm for total vaginal length Apical success: 49/49 (100.0%)
Overall succes: 45/49 (91.8%)
0/49 (0.0%)
Thomas et al. [50] POPQ stage II–IV
6 months for follow-up visit, 6.5 years for follow-up survey
Anatomic failure at 6 months: POPQ stage II or greater on examination or retreatment with pessary or surgery
Symptomatic failure at 6.5 years: a positive response to the question, “since your surgery, have you been evaluated or treated for return of your prolapse (vaginal bulge)?”
Anatomic success at 6 M: 138/173 (79.8%)
Subjective success at 6.5 years: 70/80 (87.5%)
15/173 (8.7%)
Culligan et al. [22] POPQ stage II–IV
66 (58–80)
Composite surgical failure-any of the following 4 criteria were met
Objective failure:
  • -POP-Q point C of greater than or equal to−5

  • -POP-Q points Aa, Ba, Ap, or Bp greater than 0 (i.e., beyond the hymen)

Subjective failure:
  • -Bothersome bulge symptoms reported by the participant in response to the PFDI-20 questions, “do you usually have a sensation of bulging or protrusion from the vaginal area?” or “do you usually have a bulge or something falling out that you can see or feel in the vaginal area?”

  • -POP surgery or pessary use for prolapse at any point after her index surgery

Apical success: 253/253 (100.0%)
Overall objective success: 242/253 (95.7%)
Subjective success: 226/253 (89.3%)
10/253 (3.9%)

POP, pelvic organ prolapse; POPQ, pelvic organ prolapse quantification; TVL, total vaginal length; PFDI-20, pelvic floor distress inventory-20; POPDI-6, pelvic organ prolapse distress inventory-6; NA, not available.

a)

Values presented as mean (standard deviation) or median (range).

b)

Bothersome vaginal bulge symptoms defined as “somewhat, moderately, or quite a bit bothered” (score 2–4) on question #3 of the PFDI-20, which asks “do you usually have a bulge or something falling out that you can see or feel in your vaginal area?”

c)

Measured at least 1 year after the index surgery.

d)

Weighted mean and standard deviation.

e)

Measured at 1 year after the surgery.

f)

Success rate of 70/83 (84.3%) when the definition of recurrent prolapse was changed to any prolapse at or beyond the hymen.

g)

Corresponds to POPQ stage I–IV.

h)

Descent to the hymen.

i)

Descent half way past to hymen.